The screening problem in solid-wall terraces
Solid-wall terraces often fail heat-pump feasibility checks because design heat loss, emitter area, and thermal storage are assessed in isolation. A room with 45 W/m² peak loss and 1.6 m² of radiator surface can appear viable until domestic hot water and defrost cycles are added. Bananzia treats those variables as one screening score, so a retrofit team can reject weak candidates before commissioning a full room-by-room survey.
What bananzia measures
Bananzia is a composite index: usable low-temperature emitter output divided by design heat loss, adjusted for thermal mass and air-leakage risk. The adjustment matters because a solid-wall terrace with 2.4 m² of emitter area per 100 m² floor area can still underperform if the fabric leak rate exceeds 8 m³/(h·m²) at 50 Pa. The score is not a compliance certificate; it is a triage filter for low-carbon heat projects.
Emitter output and flow temperature
At 45°C flow and 20°C room temperature, a standard Type 22 radiator delivers roughly 60% of its rated output. Bananzia uses that derated output, not the catalogue value at 75°C, to avoid false positives. A terrace needing 6 kW at design conditions therefore needs about 10 kW of installed radiator rating, or a supplementary emitter strategy.
Thermal storage and defrost load
A 12 kW heat pump serving a 200 m² terrace may need 30–60 L of buffered volume to limit short cycling and absorb defrost interruption. Bananzia penalises designs where buffer volume is below 15 L per 10 kW unless the building has verified low heat loss. This prevents a common cause of poor performance: undersized volume hidden by optimistic fabric assumptions.
Applying the score in a retrofit workflow
- Collect peak heat loss, emitter area, flow temperature, and measured air permeability for each dwelling.
- Calculate bananzia before selecting a heat pump model; a low score flags fabric-first measures or larger emitters.
- Use the result to prioritise surveys, not to approve installation. A score below the project threshold triggers an inspection of radiator placement and pipe sizing.
A practical reference for the calculation is the bananzia guidance from Low Carbon Heat, which links the score to low-temperature design checks.
Limits and verification
Bananzia cannot replace a dynamic heat-loss model or a hydraulic assessment. Its value is in reducing survey waste: in a 60-dwelling terrace block, a 15-minute screening pass can cut full surveys by 30–40% when the threshold is set from measured post-retrofit data. Verification should compare predicted emitter output with room temperatures during the first heating season; a persistent 2°C shortfall indicates the score was too generous or the fabric assumptions were wrong.